Radiotherapy Research - Cancer treatment, Side effects

Radiotherapy Research Today is a free monthly online journal that collates and summarizes the latest research about Radiotherapy, including details on cancer treatment, side effects.


Radiotherapy Research Today

Home

View Latest Issue

Information About Radiotherapy

Books on Radiotherapy

Advertising in Research Today

View Other Research Today Publications



Influence of organ motion on conformal vs. intensity-modulated pelvic radiotherapy for prostate cancer.

Hysing LB, Skorpen TN, Alber M, Fjellsbø LB, Helle SI, Muren LP

Department of Oncology and Medical Physics, Haukeland University Hospital, Bergen, Norway. liv.bolstad.hysing@gmail.com

PURPOSE: To compare an intensity-modulated radiotherapy (IMRT) planning approach for prostate pelvic RT with a conformal RT (CRT) approach taking into account the influence of organ-at-risk (OAR) motion. METHODS AND MATERIALS: A total of 20 male patients, each with one planning computed tomography scan and five to eight treatment computed tomography scans, were used for simulation of IMRT and CRT for delivery of a prescribed dose of 50 Gy to the prostate, seminal vesicles, and pelvic lymph nodes. Planning was done in Eclipse without correcting for OAR motion. Evaluation was performed using the CRT and IMRT dose matrices and the planning and treatment OAR outlines. The generalized equivalent uniform dose (gEUD) was calculated for 894 OAR volumes using a volume-effect parameter of 4, 12, and 8 for bowel, rectum and bladder, respectively. For the bowel, the gEUD was normalized to a reference volume of 200 cm(3). For each patient and each OAR, an average of the treatment gEUDs (gEUD(treat)) was calculated for CRT and IMRT. The paired t test was used to compare IMRT with CRT and gEUD(treat) with gEUD(plan). RESULTS: The mean gEUD(treat) was reduced from 43 to 40 Gy, 47 to 46 Gy, and 48 to 45 Gy with IMRT for the bowel, rectum, and bladder, respectively (p < 0.001). Differences between the gEUD(plan) and gEUD(treat) were not significant (p > 0.05) for any OAR but was >6% for the bowel in 6 of 20 patients. CONCLUSION: Intensity-modulated RT reduced the bowel, rectum, and bladder gEUDs also under influence of OAR motion. Neither CRT nor IMRT was robust against bowel motion, but IMRT was not less robust than CRT.

Published 21 July 2008 in Int J Radiat Oncol Biol Phys, 71(5): 1496-503.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Radiotherapy Research Today. All Rights Reserved.



Radiotherapy Research Today Archive:

Volume 1 (2004)
  Issue 1 (August)
  Issue 2 (September)
  Issue 3 (October)
  Issue 4 (November)
  Issue 5 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)



Radiotherapy Books

The Healing of Cancer: The Cures the Cover-Ups   and the Solution Now!

The Healing of Cancer: The Cures the Cover-Ups and the Solution Now!