Radiotherapy Research - Cancer treatment, Side effects

Radiotherapy Research Today is a free monthly online journal that collates and summarizes the latest research about Radiotherapy, including details on cancer treatment, side effects.


Radiotherapy Research Today

Home

View Latest Issue

Information About Radiotherapy

Books on Radiotherapy

Advertising in Research Today

View Other Research Today Publications



Strategy for online correction of rotational organ motion for intensity-modulated radiotherapy of prostate cancer.

Rijkhorst EJ, van Herk M, Lebesque JV, Sonke JJ

Department of Radiation Oncology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands.

PURPOSE: To develop and evaluate a correction strategy for prostate rotation using gantry and collimator angle adjustments. METHODS AND MATERIALS: Gantry and collimator angle adjustments were used to correct for prostate rotation without rotating the table. A formula to partially correct for left-right (LR) rotations was derived through geometric analysis of rotation-induced clinical target volume (CTV) beam's-eye-view shape changes. For 10 prostate patients, intensity-modulated radiotherapy (IMRT) plans with different margins were created. Simulating CTV LR rotation and correcting each beam by a collimator rotation, the corrected CTV dose was compared with the original and uncorrected dose. Effects of residual geometric uncertainties were assessed using a Monte Carlo technique. A large number of treatments representative for prostate patients were simulated. Dose probability histograms of the minimum CTV dose (D min) were derived, with and without online correction, resulting in a more realistic margin estimate. RESULTS: Dosimetric analysis of all IMRT plans showed that, with rotational correction and a 2-mm margin, D min was constant to within 3% for LR rotations up to +/-15 degrees . The Monte Carlo dose probability histograms showed that, with correction, a margin of 4 mm ensured that 90% of patients received a D min >or=95% of the prescribed dose. Without correction a margin of 6 mm was required. CONCLUSIONS: We developed and tested a practical method for (online) correction of prostate rotation, allowing safe and straightforward implementation of margin reduction and dose escalation.

Published 23 November 2007 in Int J Radiat Oncol Biol Phys, 69(5): 1608-17.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Radiotherapy Research Today. All Rights Reserved.



Radiotherapy Research Today Archive:

Volume 1 (2004)
  Issue 1 (August)
  Issue 2 (September)
  Issue 3 (October)
  Issue 4 (November)
  Issue 5 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Radiotherapy Books

Coping With Chemotherapy and Radiation Therapy

Coping With Chemotherapy and Radiation Therapy