Improvement of dose calculation accuracy for BNCT dosimetry by the multi-voxel method in JCDS.

Kumada H, Yamamoto K, Yamamoto T, Nakai K, Nakagawa Y, Kageji T, Matsumura A

Department of Research Reactor, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki, Japan. hkumada@popsvr.tokai.jaeri.go.jp

To carry out boron neutron capture therapy (BNCT) clinical trials based on accurate dosimetry of several dose components given to a patient, we had developed the JAERI computational dosimetry system (JCDS), which can determine the absorbed doses by numerical simulation. The verification results of initial version of JCDS indicated that JCDS causes characteristic discrepancy, when JCDS estimates a sharp change arising such as near the surface. The aim of this study is to improve the accuracy of the BNCT dosimetry efficiently. The multi-voxel calculation method that reconstructs the original voxel model by combining several voxel cell sizes such as 0.125, 1 and 8 cm(3) has been developed. To verify the accuracy of the method, the calculation results were compared with the phantom experimental data. Furthermore, to verify its practicality to BNCT, retrospective evaluation of an actual BNCT in JRR-4 was performed by the multi-voxel method. The results of the comparison with the phantom experiments demonstrated that the calculation accuracy for the distributions of the thermal neutron flux was improved by employing the multi-voxel method. The computing time using the multi-voxel method increased only approximately 33% compared to the conventional uniform 1cm(3) voxel method. These results proved that the multi-voxel calculation enables JCDS to more accurately estimate the absorbed doses to a patient by efficient calculations.

Published 13 August 2004 in Appl Radiat Isot, 61(5): 1045-50.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Radiotherapy Research Today. All Rights Reserved.



Radiotherapy Research Today Archive:

Volume 1 (2004)
  Issue 1 (August)
  Issue 2 (September)
  Issue 3 (October)
  Issue 4 (November)
  Issue 5 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Radiotherapy Books

A Guide for Delineation of Lymph Nodal Clinical Target Volume in Radiation Therapy

A Guide for Delineation of Lymph Nodal Clinical Target Volume in Radiation Therapy